Você está na página 1de 5

Técnicas para Avaliar a Hidratação

e a Oleosidade da Pele
Maísa Oliveira de Melo, Patrícia MBG Maia Campos
Faculdade de Ciências Farmacêuticas de Ribeirão Preto – USP, Ribeirão Preto SP, Brasil

O Corneometer
CM 825

Conteúdo Aquoso da Pele

Corneometer CM 825
Corneometer CM 820

30/Cosmetics & Toiletries (Brasil) Vol. 28, mar-abr 2016


Skincon 200 EX Corneometer CM 825
Dermalab
Nova
Derm Phase Meter DPM 9003 Corneometer CM 825

Corneometer CM 825 Nova DPM 9003

Skincon 200 EX

Skincon 200 EX
Corneometer CM 825
Nova DPM 9003
Corneometer CM 825
Skin
Chip Skincon 200 EX
in vivo

kincon 200
EX Corneometer
Corneometer CM 825 CM 825

Corneometer
CM 825

Vol. 28, mar-abr 2016 Cosmetics & Toiletries (Brasil)/31


Tabela 1. Instrumentos e princípios para medir a hidratação da pele

Instrumento Método Propriedades


Corneometer CM 825 Mais preciso e estável em pele seca.
Capacitância
(Courage + Khazaka) Sofre influências das características da pele.
Skincon 200 EX Mais sensível em peles bem-hidratadas,
Condutância
(IBS Ltd.,) Medições mais superficiais.
Tem a opção de sondas com 8 pinos,
Dermalab (Cortex) Condutância
ideal para medições em pele seca e no couro cabeludo.
Nova Derm Phase Meter – Medições de ângulo de fase, Medições mais superficiais,
Impedância
DPM 9003 (Nova Technology) Pouca variância.
Skin Chip (L´Oréal) Capacitância (microssensor) Útil para o mapeamento da capacitância da superfície da pele.

Tabela 2. Instrumentos e dispositivos utilizados nos métodos de medição direta e indireta da oleosidade da pele

Instrumentos/dispositivos Método Propriedades


Lipometer (L´Oréal) Vidro opaco Altera a transmitância da luz quando impregnado por lipídeos
Sebumeter SM 820
Fita translúcida Altera a transmitância da luz quando impregnada por lipídeos
(Courage + Khazaka)
Sebutape Produz manchas na superfície da fita
Fita adesiva
(CuDerm) quando impregnada por lipídeos
Sebufix F16 Produz manchas na superfície da fita,
Fita adesiva
(Courage + Khazaka) quando impregnada por lipídeos
Visioscan VC 98 Um software faz a análise de imagem da fita
Câmera com iluminação UVA1
(Courage + Khazaka) Sebufix F16 e quantifica o teor de lipídeos
Skin-Glossymeter GL 200 Medição indireta. O brilho da pele pode estar
Reflectância
(Courage + Khazaka) relacionado com o teor de lipídeos
Visiopore P 34
Fluorescência Medida indireta por meio da medição do índice de porifinas
(Courage + Khazaka)

Quantidade de Sebo da Pele

32/Cosmetics & Toiletries (Brasil) Vol. 28, mar-abr 2016


Sebutape Sebufix F16

Lipometer
Sebumeter SM 820

Visioscan VC 98
Visioscan VC 98
Sebufix F16

Skin-Glossymeter GL 200

Vol. 28, mar-abr 2016 Cosmetics & Toiletries (Brasil)/33


Visiopore PP 34 Referências
1. Agache P. Scoring acne vulgaris. In: Agache P, Humbert P, Maibach
HI. Measuring the Skin: Non-invasive Investigations, Physiology,
Normal Constants. Springer-verlag, Berlim, 2004
2. Barel AO et al. Non-invasive electrical measurements for evaluating
the water content of the horny layer: comparison between capacitance
and conductance measurements. In: Scott RC et al. Prediction of
percutaneous penetration: methods, measurements, modelling. Ibc
Propionibacterium acnes Technical Services Ltd., Londres, 1991
3. Berardesca E. EEMCO Guidance for the asssessment of stratum cor-
neum hydration: electrical methods. Skin Res Tech 3(2):126-132, 1997
4. Blichmann C, Serup J. Assessment of skin moisture. Acta Derm
Venereol 68:284-290, 1988
5. Darlenski R, Fluhr JW. Moisturizers and Emollients. In: Fluhr JW. Prac-
tical Aspects of Cosmetic Testing. Springer-verlag, Berlim, 2011
6. Dobrev H. Products for Impure, Acne-Like Skin. In: Fluhr JW. Practical
Aspects of Cosmetic Testing. Springer-verlag, Berlim, 2011
P. acnes 7. El-Gammal C, El-Gammal S. Sebum-absorvent tape and image
analysis. In: Serup J, Jemec GBE. Handbook of Non-invasive Methods
and the Skin. CRC Press, Boca Raton, 1995
8. Hatzis J, Marks R. The relationship between conductance and ca-
Propionibacterium acnes pacitance measurements and skin surface contour during hydration
of the stratum corneum. In: Marks R, Plewig G. Stratum corneum.
Visiopore PP 34 Springer-Verlag, Berlin, Heidelberg, New York, 1993
9. Heinrich U et al. Multicentre comparison of skin hydration in terms of
Propionibacterium acnes physical-, physiological and product-dependent parameters by the
capacitive method (Corneometer CM 825). Int J Cosmet Sci 25:45-53,
2003
10. HUA, W. et al. Comparison of two series of non-invasive instruments
in vivo used for the skin physiological properties measurements: the ‘Soft
Plus’ from Callegari S.p.A vs. the series of detectors from Courage
& Khazaka. Skin Research and Technology, Copenhagen, n. 20,
p.74–80, 2014.
11. Melo MO et al. Eficácia clínica de formulações cosméticas contendo
derivado de vitamina B6 na proteção da pele oleosa. In: Congresso
Brasileiro de Cosmetologia, 28o, 2014. Associação Brasileira de
Cosmetologia, São Paulo, 2014
12. O’Goshi K, Serup J. Inter-instrumental variation of skin capacitance
measured with the Corneometers. Skin Res Tech 4:107-109, 2005
13. Obata M, Tagami H. Electrical determination of water content and
concentration profile in a simulation model of in vivo stratum corneum.
J Invest Dermatol 92:854-859, 1989
14. Aye M, Van de Gaer D, Morrison BM. Corneometry measurements
Pyridoxine tris- to evaluate skin drvness in the modified soap chamber test. Skin Res
-hexydecanoate Tech 1:123-127, 1995
15. Piérard GE, Khazaka D, Khazaka G. Sunscreen remanence on the
skin: a noninvasive real time in vivo spectral analysis assessing the
quenching of specular ultraviolet A light reflectance. J Cosm Dermat
doi: 10.1111/jocd.12169, 2015
16. Piérard GE, Uhoda I, Piérard-Franchimont C. From skin microrelief to
wrinkles. An area ripe for investigation. J Cosm Derm 2:21–28, 2003
17. Piérard GE et al. EEMCO Guidance for the in vivo Assessment of
Skin Greasiness. Skin Pharm Appl Skin Physiol 9:372-389, 2000
18. Salter DC. Monitoring human skin hydration in vivo using electrical
impedance - a model of skin as a solid ionic conductor. Proceedings IX
International Conference on Electrical Bio-Impedance and European
Community Concerted Action on Impedance Tomography, Heidelberg,
1995
19. Tagami H. Hardware and measuring principle: skin conductance. In:
Elsner P, Berardesca E, Maibach H. Bioengineering of the skin: water
Conclusão and the stratum corneum. CRC Press, Boca Raton, 1994
20. Uhoda E, Leveque JL, Pierard GE. Silicon image sensor technology
for in vivo detection of surfactante-induced corneocyte swelling and
drying. Dermatology 210(3):184-188, 2005
21. Wickett RR, Mutschelknaus JL, Hoath SB. Ontogeny of water sorption-
-desorption in the perinatal rat. J Invest Dermatol 100:407-411,
1993

34/Cosmetics & Toiletries (Brasil) Vol. 28, mar-abr 2016

Você também pode gostar