Vagner Sales dos Santos , Luzia Márcia de Melo Silva2, Francinalva Cordeiro de Sousa3 Djaneide Sales dos Santos4 e Anielle dos Santos Brito5
RESUMO -O presente trabalho tem como objetivo avaliar a eficiência de remoção de DQO e DBO em um reator
UASB. Esta pesquisa realizou-se na estação de tratamento de esgotos do município do Crato - CE, em um reator
anaeróbio de fluxo ascendente com manta de lodo (reator UASB), em escala piloto, pertencente à Faculdade de
Tecnologia – CENTEC Cariri – CE. E o monitoramento, foi realizado por meio de amostras coletadas quinzenalmente
na entrada (afluente) e saída (efluente) do reator, o que possibilitou-se analisar os seguintes parâmetros: pH,
temperatura, demanda química de oxigênio (DQO), demanda bioquímica de oxigênio (DBO). De acordo com os
resultados obtidos conclui-se que o pH no afluente e efluente apresentou resultados satisfatórios mantendo-se dentro
da faixa neutra, no que se refere aos valores de temperatura no afluente e efluente foi considerada ótima para a
digestão anaeróbia. Com relação à eficiência de remoção de matéria orgânica expressa na forma de DQO e DBO,
apresentaram valores em torno de 44 e 76 % e de 16 e 76%, respectivamente. Contudo, deve-se ressaltar que a
eficiência de remoção de DQO e de DBO foi baixa. Este fato foi atribuído à descontinuidade da alimentação do reator
UASB ser praticamente desprezível no período noturno.
ABSTRACT -The present study aims to evaluate the removal efficiency of COD and BOD in a UASB reactor. This
research was carried out in sewage treatment plant in the municipality of Crato - EC in an upflow anaerobic sludge
blanket (UASB), pilot scale, belonging to the Faculty of Technology - CENTEC Cariri - EC. And the monitoring was
conducted by means of samples collected biweekly at the inlet (influent) and output (effluent) from the reactor, which
allowed to analyze the following parameters: pH, temperature, chemical oxygen demand (COD), biochemical demand
for oxygen demand (BOD). According to the results obtained it was concluded that pH in the influent and effluent
showed satisfactory results remaining within the neutral range, in the case of temperature values in the influent and
effluent was considered optimal for the anaerobic digestion. With regard to the efficiency of removal of organic
substance in the form of COD and BOD values were around 44 and 76% and 16% and 76, respectively. However, it
should be noted that the removal efficiency of COD and BOD was low. This was attributed to the discontinuity of the
power of the UASB reactor is negligible at night.
16-20
Vagner Sales dos Santos, et al.
Figura 1: Vista de frente do reator UASB Figura 2: Vista de lado do reator UASB
procedimentos analíticos encontram-se descritos em for the Examination of Water and Wastewater (APHA,
American Public Health Association / Standard Methods 1998).
8
Potêncial Hidrogeniônico
7,8
7,6
(pH)
7,4
7,2
6,8
EXP 1 EXP 2 EXP 3 EXP 4 EXP 5
Experimento
Afluente Efluente
16-20
Vagner Sales dos Santos, et al.
30
Temperatura (°C)
29
28
27
26
25
24
EXP 1 EXP 2 EXP 3 EXP 4 EXP 5
Experimento
Afluente Efluente
80
70
60
Eficiência
50
40
30
20
10
EXP 1 EXP 2 EXP 3 EXP 4 EXP 5
Experimento
DQO DBO
16-20