RESUMO
INTRODUO
padro
de
Hipoclorito
de
sdio,
7,3%
(Procedncia
BONDMANN QUIMICA).
Todas as solues foram preparadas com gua desmineralisada (<1 S).
Foram utilizados como vidrarias: pipetas volumtricas de 5 e 10 mL,
erlenmeyer de 250mL, bureta graduada de 50mL, balo volumtrico de 100mL e
proveta graduada de 50mL.
No procedimento de anlise pipetou-se 10 mL de amostra para o balo de
100 mL, avolumou-se o balo com gua destilada e homogeneizou-se. Em seguida
transferiu-se 10 mL da soluo de KI 10 % para o erlenmeyer, utilizando-se a uma
proveta de 50 mL.
Pipetou-se 5 mL da soluo preparada para o erlenmeyer, adicionou-se 20
mL de cido actico 1:3 e titulou-se rapidamente com Na2S2O3 0,10 N at a cor
amarelo claro. A titulao foi iniciada imediatamente aps a adio do cido actico
para evitar a perda de iodo. Durante o tempo da titulao o erlenmeyer foi
constantemente agitado.
Concentrao Terica / %
6,00
y = 1,031x + 0,030
R = 0,999
5,00
4,00
3,00
2,00
1,00
0,00
0,00
1,00
2,00
3,00
4,00
5,00
6,00
Concentrao Real / %
Figura 1 Representao grfica da concentrao Terica em funo da
mdia da concentrao Real.
VG
Conc. (%)
Procedncia da
Amostra.
3,6
3,5 0,1
Lins
1,7
1,6 0,1
Lins
4,3
4,1 0,1
Penpolis
2,8
2,7 0,1
Guaiara
2,1
2,0 0,1
Promisso
3,6
3,5 0,1
Pongai
CONCLUSO
ABSTRACT
Used in certain cases and for different purposes, sodium hypochlorite is frequently
found in bleach, especially in Brazil. But with the growing illegal production became
possible because the consumer is being harmed. The aims of this work aims was the
implementation and validation of the NBR-9425 - ABNT - Sodium hypochlorite Determination of active chlorine. For the development and validation, calibration
curve was constructed in a range of concentration from 0.5% to 5.0%. Was evaluated
all the necessary requirements for validation: selectivity, linearity, precision,
accuracy, detection limit, quantification limit and ruggedness. After the validation,
samples of bleaches sold clandestinely in the Lins region were evaluated. The results
showed the non-conformity with the decree n 89/94 , which defaults to the content of
2.00% w / w 2.5% p / p. This work showed that validation tool is adequate and
proved that the technique is sensitive to low concentrations of sodium hypochlorite,
showing yet that the results of the tests performed allow an evaluation of specific
parameters as ensuring the implementation of the method and reliability of analytical
results.
REFERNCIAS
AUTORES:
Luiz Gustavo Nerva Licenciando em Qumica
E-mail: gustavo_nerva@hotmail.com
Odair Paduan Licenciando em Qumica
E-mail: odair_works@hotmail.com
Renato Mariano Licenciando em Qumica
E-mail: renato.mariano@ceteclins.com.br
Vincius Sanches Matsura Licenciando em Qumica
E-mail: vinicius_matsura@hotmail.com
ORIENTADOR:
Prof. Me. Olayr Modesto Junior
E-mail: olayr@unisalesiano.edu.br