Escolar Documentos
Profissional Documentos
Cultura Documentos
JOINVILLE
NOVEMBRO / 2018
2
JOINVILLE
NOVEMBRO / 2018
3
4
AGRADECIMENTOS
RESUMO
ABSTRACT
This work presents the dynamic modeling for a permanent magnet current
(PMDCM) motor and for a three-phase induction motor (TPIM). In both cases the
equivalent circuit is presented and the mathematical equations of the model. For
TPIM, a conversion of the abc system to αβ through the Clarke's Transform and
then to dq0 through the Park transform is done to make a brief evaluation of the
system in the straight-axis and quadrature system.
For the dynamic modeling of the PMDCM, we used parameters of a didactic
model with a simpler purpose, focused on understanding and leaving aside more in-
depth studies. For TPIM, before the dynamic modeling, laboratory tests were carried
out with a real machine to survey the parameters of resistances and reactances,
and after this stage the dynamic modeling.
The results obtained help to understand the behavioral characteristics of the
motors, leading to an understanding of how we can change the speed of an
PMDCM, its behavior before the load, among other characteristics. In the TPIM
modeling, exhaustive simulations were performed for the most varied situations that
the same can suffer with the balanced alteration of its supply voltage and load
torque.
Key Words: Permanent Magnet DC Motor, Three Phase Induction Motor, Modeling
a TPIM.
9
LISTA DE ILUSTRAÇÕES
LISTA DE TABELAS
LISTA DE SÍMBOLOS
SUMÁRIO
1. INTRODUÇÃO ............................................................................................... 20
3. O MOTOR DE INDUÇÃO............................................................................... 34
REFERÊNCIAS ..................................................................................................... 84
APÊNDICES.......................................................................................................... 85
20
1. INTRODUÇÃO
.
22
Com base no modelo acima, as equações que o compõe são definidas. Antes
da definição a tensão de armadura 𝑉 (𝑡), primeiramente é necessário a definir as
parcelas que a compõe, que são a tensão no resistor 𝑅 , a tensão no indutor 𝐿 e
a força eletromotriz induzida na armadura ou Back-EMF 𝑒(𝑡), que são mostradas a
seguir:
Tensão no resistor - 𝑉 :
𝑑𝐼 (𝑡)
𝑉 (𝑡) = 𝐿 . (2)
𝑑(𝑡)
𝑒(𝑡) = 𝐾 . 𝜙. 𝜔 (3)
24
𝑒(𝑡) = 𝐾 . 𝜔 (4)
𝑑𝐼 (𝑡)
𝑉 (𝑡) = 𝑅 . 𝐼 (𝑡) + 𝐿 . + 𝐾 .𝜔 (5)
𝑑(𝑡)
𝜏 = 𝐾 . 𝜙. 𝐼 (𝑡) (6)
Da mesma forma que foi feito com a tensão na armadura, omitiremos o fluxo
também na equação do torque induzido, ficando:
𝜏 = 𝐾 . 𝐼 (𝑡) (7)
𝑑𝜔 (𝑡)
𝜏 = 𝛽. 𝜔 + 𝐽. + 𝑇 (8)
𝑑(𝑡)
𝑑𝑖 (𝑡) 𝑉 𝑅 .𝐼 𝐾. 𝜔
= − − (9)
𝑑(𝑡) 𝐿 𝐿 𝐿
𝑑𝜔 (𝑡) 𝑇 𝐾. 𝐼 𝛽. 𝜔
=− + − (10)
𝑑(𝑡) 𝐽 𝐽 𝐽
̇ = 𝐴. 𝑋(𝑡) + 𝐵. 𝑈(𝑡)
𝑋(𝑡) (11)
̇ , temos:
Na Equação de Estados 𝑋(𝑡)
𝐴, que é uma matriz de sistema;
𝑋(𝑡), que é o vetor de estados;
𝐵, que é outra matriz de sistema;
𝑈(𝑡), que é a matriz de entradas;
𝑅 𝐾
⎡− − ⎤
𝐿 𝐿 ⎥
𝐴=⎢ (12)
⎢ 𝐾 𝛽
− ⎥
⎣ 𝐽 𝐽⎦
𝐼
𝑋(𝑡) = (13)
𝜔
1
⎡ 0 ⎤
𝐿
𝐵=⎢ ⎥ (14)
⎢0 1⎥
−
⎣ 𝐽⎦
𝑉
𝑈(𝑡) = (15)
𝑇
𝑅 𝐾 1
⎡− − ⎤ ⎡ 0 ⎤
̇ =⎢ 𝐿
𝑋(𝑡)
𝐿 ⎥ 𝐼
. +⎢
𝐿 ⎥. 𝑉 (16)
⎢ 𝐾 𝛽⎥ 𝜔 ⎢0 1 𝑇
− − ⎥
⎣ 𝐽 𝐽⎦ ⎣ 𝐽⎦
3. O MOTOR DE INDUÇÃO
onde:
𝑅 : Resistência do estator, que representa as perdas joule do enrolamento do
estator;
𝑗𝑋 : Reatância de dispersão do estator, que representa a parcela referente
aos fluxos que enlaçam totalmente ou parcialmente os enrolamentos do estator,
entretanto, não contribuem para o fluxo útil do motor, ou seja, fluxo mútuo entre
estator e rotor;
𝑅𝑟: Resistência do rotor refletida ao estator, que representa a parcela das
perdas joules das barras curto-circuitadas do rotor;
𝑗𝑋 : Reatância de dispersão do rotor refletida ao estator por fase, que
representa a parcela referente aos fluxos que enlaçam totalmente ou parcialmente
as barras do rotor, entretanto, como no caso do estator, não contribuem para o fluxo
útil do motor;
𝑅 : Resistência correspondente às perdas do núcleo, que representa as
perdas magnéticas no núcleo por fase do motor devido as correntes parasitas e ao
fenômeno de histerese magnética, que são, respectivamente, perdas por correntes
induzidas nas chapas do núcleo laminado do motor e as perdas devido às
densidades de fluxo;
𝑗𝑋 : Reatância de magnetização, que representa a parcela do fluxo útil no
motor, ou seja, o fluxo mútuo entre o estator e o rotor, que é o responsável pela
indução de tensão nas barras do rotor.
36
𝐕 = 𝐫 .𝐢 + 𝑝. 𝛌 (17)
𝐕 = 𝐫 .𝐢 + 𝑝. 𝛌 (18)
o operador "𝑝” representa a derivada do item que o sucede, que neste caso é o
fluxo concatenado que é expresso pela equação (19),
𝛌 𝐋 𝐋 𝐢
= . (19)
𝛌 (𝐋 ) 𝐋 𝐢
1 1
⎡𝐿 + 𝐿 − .𝐿 − .𝐿 ⎤
⎢ 2 2 ⎥
1 1
𝐋 = ⎢− .𝐿 𝐿 +𝐿 − .𝐿 ⎥ (20)
⎢ 2 2 ⎥
⎢ 1 1 ⎥
⎣−2.𝐿 − .𝐿
2
𝐿 +𝐿 ⎦
39
1 1
⎡𝐿 + 𝐿 − .𝐿 − .𝐿 ⎤
⎢ 2 2 ⎥
1 1
𝐋 = ⎢− .𝐿 𝐿 +𝐿 − .𝐿 ⎥ (21)
⎢ 2 2 ⎥
⎢ 1 1 ⎥
⎣−2.𝐿 − .𝐿
2
𝐿 +𝐿 ⎦
2𝜋 2𝜋
⎡ 𝑐𝑜𝑠𝜃 𝑐𝑜𝑠 𝜃 + 𝑐𝑜𝑠 𝜃 − ⎤
⎢ 3 3 ⎥
2𝜋 2𝜋
𝐋 = 𝐿 ⎢𝑐𝑜𝑠 𝜃 − 𝑐𝑜𝑠𝜃 𝑐𝑜𝑠 𝜃 + ⎥ (22)
⎢ 3 3 ⎥
⎢ 2𝜋 2𝜋 ⎥
⎣𝑐𝑜𝑠 𝜃 + 3 𝑐𝑜𝑠 𝜃 −
3
𝑐𝑜𝑠𝜃 ⎦
𝑁
𝐢 = .𝐢 (23)
𝑁
𝑁
𝐯 = .𝐯 (24)
𝑁
𝑁
𝛌 = .𝛌 (25)
𝑁
2𝜋 2𝜋
⎡ 𝑐𝑜𝑠𝜃 𝑐𝑜𝑠 𝜃 + 𝑐𝑜𝑠 𝜃 − ⎤
⎢ 3 3 ⎥
𝐋 =𝐿 ⎢𝑐𝑜𝑠 𝜃 − 2𝜋 𝑐𝑜𝑠𝜃 𝑐𝑜𝑠 𝜃 +
2𝜋 ⎥ (26)
⎢ 3 3 ⎥
⎢ 2𝜋 2𝜋 ⎥
⎣𝑐𝑜𝑠 𝜃 + 3 𝑐𝑜𝑠 𝜃 −
3
𝑐𝑜𝑠𝜃 ⎦
40
1 1
⎡𝐿 + 𝐿 − .𝐿 − .𝐿 ⎤
⎢ 2 2 ⎥
1 1
𝐋 = ⎢− .𝐿 𝐿 +𝐿 − .𝐿 ⎥ (27)
⎢ 2 2 ⎥
⎢ 1 1 ⎥
⎣−2.𝐿 − .𝐿
2
𝐿 +𝐿 ⎦
𝛌 𝐋 𝐋 𝐢
= . (28)
𝛌 (𝐋 ) 𝐋 𝐢
𝐕 𝐫 + 𝑝. 𝐋 𝑝. 𝐋 𝐢
= . (29)
𝐕 𝑝. (𝐋 ) 𝐫 + 𝑝. 𝐋 𝐢
𝑃 1 1 1 1
𝑇 =− . 𝑖 . 𝑖 − .𝑖 − .𝑖 +𝑖 . 𝑖 − .𝑖 − .𝑖
2 2 2 2 2
1 1
+𝑖 . 𝑖 − .𝑖 − .𝑖 . 𝑠𝑖𝑛𝜃
2 2
(30)
√3
+ . [𝑖 . (𝑖 − 𝑖 ) + 𝑖 . (𝑖 − 𝑖 )]
2
+ 𝑖 . (𝑖 − 𝑖 ). 𝑐𝑜𝑠𝜃
sistemas “αβ” e “dq0” através das Transformadas de Clarke e Park, onde a análise
gráfica torna-se linear, de forma similar a um motor CC
1 1
⎡1 − − ⎤
𝑆 ⎢ 2 2⎥
2 𝑆
𝑆 = ⎢0 √3 −
√3⎥ . 𝑆 (31)
3⎢ 2 2⎥ 𝑆
𝑆
⎢1 1 1 ⎥
⎣2 2 2 ⎦
𝜃 = 𝑎𝑡𝑎𝑛2 𝑓 , 𝑓 (33)
45
4.1. ENSAIO CC
𝑉
𝑅 = (34)
2 .𝐼
𝑉
|𝑍 |= (35)
𝐼 ( )
𝑃 = 3. 𝐼 ( ) .𝑅 (36)
𝑃 =𝑃 _ −𝑃 (37)
𝑅 =𝑅 −𝑅 (38)
onde 𝑅 :
𝑅 = 𝑍 . cos(𝜃) (39)
sendo:
𝑉
|𝑍 | = (40)
√3. 𝐼 ( )
e:
𝑃 _ (41)
𝜃 = cos
√3. 𝑉 . 𝐼 ( )
onde uma vez que normalmente o ensaio de rotor bloqueado por norma é feito com
frequências abaixo da frequência nominal do motor, calcula-se 𝑋 :
𝑋 = 𝑍 . sin(𝜃). (42)
|𝑋 | = .𝑋 . (43)
𝑋 = |𝑍 |−𝑋 .
A velocidade a vazio é apresentada na Figura 21, onde podemos ver que seu
valor é muito próximo da velocidade síncrona para um motor de 4 pólos em 60Hz
que é de 1800 rpm. Isso se deve ao fato de que quando um MIT está a vazio, o
escorregamento é quase igual a zero, neste caso foi encontrado um valor de
aproximadamente 0,6%.
30,00
20,00
10,00
2,80
0,00
-10,00
-20,00
-30,00
-40,00
0,000 0,050 0,100 0,150 0,200 0,250 0,300
Esse alto valor de corrente partida explica o motivo pelo qual no passado
utilizava-se de partidas de motores com tensões reduzidas utilizando-se de
autotransformadores.
A Figura 25 mostra o comportamento já em regime permanente das correntes
para as variações de tensões citadas na avaliação da Figura 24.
57
Nas simulações com o motor sob carga nominal, foi empregada a tensão
nominal, V=380Vca, uma sobretensão de 20%, V=456Vca e uma subtensão de
15%, V=323Vca.
Assim como na análise referente a Figura 24, ao analisar a Figura 30 observa-
se o mesmo comportamento já visto anteriormente. Com tensão nominal temos a
corrente de pico de 26,79A, com a sobretensão de 20% a corrente de pico de
26,79A e com a subtensão de 15% tem-se 22,81A, esta última correspondendo a
15% de redução em relação a corrente com tensão nominal.
Na
Figura 34 e na Figura 35, nota-se o efeito da alteração de tensão sobre o
torque eletromagnético gerado na partida do MIT. Mais uma vez, assim como a
velocidade, tem seu pico alterado diretamente proporcional à tensão aplicada.
63
A Figura 45, em comparação com a Figura 43, mostra que a corrente iqs
apresentou um módulo muito maior que a corrente ids.
Pode-se comparar o resultado da Figura 45 com o resulta apresentado na
Figura 31, onde temos aproximadamente 4,91A e o resulto encontrado aqui com a
soma vetorial é de 4,91A.
Para que um motor não venha a travar com a queda de tensão, é necessário
que o torque eletromagnético, apresentado na Figura 49, compense a necessidade
de torque solicitada pela carga. Esse aumento da necessidade de torque
eletromagnético é compensado ao custo do aumento da corrente de estator, já
apresentada Figura 47. Porém a partir de t=4 segundos o torque já não mais
consegue suportar a necessidade solicitada pela carga e o motor vem a travar.
Figura 57 - Fluxo de Potência no MIT partindo com carga nominal e tendo sua
carga aumentada ao longo do tempo
REFERÊNCIAS
KRAUSE, Paul C. Analysis of electric machinery and drive systems. 3rd ed.
Piscataway: IEEE Press, 2013. 659 p.
ZILL, Dennis G.; CULLEN, Michael R. Equações diferenciais. 3. ed. São Paulo:
Pearson Makron Books, 2006-2012.
85
APÊNDICES
B.1 - CÁLCULOS:
%% PARÂMETROS DE SIMULAÇÃO:
tsim = 6; % tempo de simulação
passo = 1e-3; % passo de simulação
nit = ceil(tsim/passo); % número de iterações
%% DADOS DO MOTOR:
Ra = 8; % [ohm] resistência de armadura
La = 10e-3; % [H] reatância de armadura
k = 0.01; % constante ref a construção mecânica
J = 1e-6; % [Kg.m2/s2] momento de inércia
B = 5e-6; % [N.m] coeficiente de atrito viscoso
ia(i) = x(1);
wr(i) = x(2);
91
torque(i) = k*ia(i);
rpm(i) = x(2)* (60/(2*pi));
end
%% SAÍDA DE DADOS:
va_500 = va;
tempo_500 = tempo;
torque_500 = torque;
ia_500 = ia;
wr_500 = wr;
rpm_500 = rpm;
save('500','va_500','tempo_500','torque_500','ia_500','wr_500','rpm_500')
;
%Figure 1:
figure;
plot(tempo_500, va_500,'k', 'linewidth',0.7);
%xlim ( [ 0.1 0.2 ] );
ylim ( [ 0 120 ] );
title('Tensão na Armadura','FontSize',12);
legend('va');
xlabel('Tempo (s)', 'FontSize',10);
ylabel('Tensão (Vcc)', 'FontSize',10);
set(gca,'linewidth',1.2);
grid on;
%Figure 2:
figure;
plot(tempo_500, torque_500, 'k', 'linewidth',0.7);
%xlim ( [ 0.1 0.2 ] );
%ylim ( [ 0 120 ] );
title('Torque','FontSize',12);
legend('torque');
xlabel('Tempo [s]', 'FontSize',10);
ylabel('Torque [N.m]', 'FontSize',10);
set(gca,'linewidth',1.2);
grid on
%Figure 3:
figure;
plot(tempo_500, ia_500, 'k', 'linewidth',0.7);
%xlim ( [ 0.1 0.2 ] );
%ylim ( [ 0 120 ] );
title('Corrente de Armadura','FontSize',12);
legend('ia');
xlabel('Tempo [s]', 'FontSize',10);
92
%Figure 4:
figure;
plot(tempo_500,rpm_500, 'k', 'linewidth',0.7);
%xlim ( [ 0.1 0.2 ] );
%ylim ( [ 0 120 ] );
title('Velocidade','FontSize',12);
legend('rpm');
xlabel('Tempo [s]', 'FontSize',10);
ylabel('Velocidade [rpm]', 'FontSize',10);
set(gca,'linewidth',1.2);
grid on;
%Figure 5:
figure;
plot(tempo_500, wr_500, 'k', 'linewidth',0.7);
%xlim ( [ 0.1 0.2 ] );
%ylim ( [ 0 120 ] );
title('Velocidade','FontSize',12);
legend('wr');
xlabel('Tempo [s]', 'FontSize',10);
ylabel('Velocidade [rad/s]', 'FontSize',10);
set(gca,'linewidth',1.2);
grid on;
%Figure 6:
figure;
plot(wr_500, torque_500, 'k', 'linewidth',0.7);
%xlim ( [ 0.1 0.2 ] );
%ylim ( [ 0 120 ] );
title('Velocidade vs Torque','FontSize',12);
legend('wr vs torque');
xlabel('Velocidade [rad/s]', 'FontSize',10);
ylabel('Torque [N.m]', 'FontSize',10);
set(gca,'linewidth',1.2);
grid on;
93
C.1 - CÁLCULOS:
%% CONDIÇÕES INICIAIS:
wrx(1:nit) = 0;
Te(1:nit) = 0;
tt(1:nit) = 0;
wr = 0;
theta_r = 0;
theta_s(1:nit) = 0;
wrmec(1:nit) = 0;
ang(1:nit) = 0;
rpm(1:nit) = 0;
i = 0;
Te1 = 0;
TL = 0;
poutt(1:nit) = 0;
f_ref(1:nit) = 60;
theta_s = 0;
theta_s_ant = 0;
% v_ref2 = 0.7*v_ref;
% end
% if(t > tmax*0.5)
% v_ref2 = 0.7*v_ref;
% end
% if(t > tmax*0.6)
% v_ref2 = 0.6*v_ref;
% end
% if(t > tmax*0.7)
% v_ref2 = 0.43*v_ref;
% end
% if(t > tmax*0.8)
% v_ref2 = 0.4*v_ref;
% end
% if(t > tmax*0.9)
% v_ref2 = 0.35*v_ref;
% end
% Indutância do Estator:
Ls = [lls+lm -1/2*lm -1/2*lm;
-1/2*lm lls+lm -1/2*lm;
-1/2*lm -1/2*lm lls+lm];
% Indutância do Rotor:
Lr = [llr+lm -1/2*lm -1/2*lm;
-1/2*lm llr+lm -1/2*lm;
-1/2*lm -1/2*lm llr+lm];
Lsr' Lr];
% Fluxo Total:
fluxo1 = [fas1;fbs1;fcs1;far1;fbr1;fcr1];
% Avanço Angular:
dtheta = passo * wr1;
theta1 = theta_r + dtheta;
%% Transformada de Clarke:
% % % f_alfa(i) = sqrt(2/3) *(fass(i) -0.5*fbss(i) -0.5*
fcss(i));
% % % f_beta(i) = sqrt(2/3) *( sqrt(3)/2*fbss(i) -
sqrt(3)/2*fcss(i));
f_alfa(i) = 2/3 * (fass(i) -1/2*fbss(i) -1/2*fcss(i));
f_beta(i) = 2/3 * ( sqrt(3)/2*fbss(i) -sqrt(3)/2*fcss(i));
98
%% Transformada de Park:
Ks = (2/3)*[ cos(theta_s(i)), cos(theta_s(i) - 2*pi/3),
cos(theta_s(i)+2*pi/3);
-sin(theta_s(i)), -sin(theta_s(i) - 2*pi/3), -
sin(theta_s(i)+2*pi/3);
0.5 , 0.5 , 0.5
];
wrx(i) = wr1;
wrmec(i) = wr1*2/P;
Te(i) = Te1;
rpm(i) = 60/2 /pi * wrmec(i);
theta_r = theta1;
wr = wr1;
ang(i) = theta_r;
fluxo = fluxo1;
corrente = corrente1;
poutt(i)= TL * (wr1*2/P);
end
tt_410 = tt;
iass_410 = iass;
ibss_410 = ibss;
icss_410 = icss;
iarr_410 = iarr;
ibrr_410 = ibrr;
icrr_410 = icrr;
va_410 = va;
99
vb_410 = vb;
vc_410 = vc;
wrmec_410 = wrmec;
Te_410 = Te;
fass_410 = fass;
fbss_410 = fbss;
fcss_410 = fcss;
farr_410 = farr;
fbrr_410 = fbrr;
fcrr_410 = fcrr;
vds_410 = vds;
vqs_410 = vqs;
ids_410 = ids;
iqs_410 = iqs;
fds_410 = fds;
fqs_410 = fqs;
pin_410 = 3/2*((vds.*ids)+(vqs.*iqs));
pconv_410 = Te .* wrmec;
pout_410 = poutt;
save('410','tt_410','iass_410','ibss_410','icss_410','iarr_410','ibrr_410
','icrr_410',...
'va_410', 'vb_410', 'vc_410','wrmec_410', 'Te_410',
'fass_410','fbss_410',...
'fcss_410','farr_410','fbrr_410','fcrr_410',...
'vds_410','vqs_410','ids_410','iqs_410','fds_410','fqs_410',...
'pin_410','pconv_410','pout_410');
if num == 1
MOTOR = MOTOR01;
elseif num == 2
MOTOR = MOTOR02;
elseif num == 3
MOTOR = MOTOR03;
elseif num == 4
MOTOR = MOTOR04;
elseif num == 5
MOTOR = MOTOR05;
elseif num == 8
MOTOR = motor_J;
end
end
% Figura 1:
% Plotagem da Tensão na fase A do Estator:
figure;
plot(tt_410,va_410,'k', 'linewidth',0.7);
% xlim ( [ 0.1 0.2 ] );
ylim ( [ -400 400 ] );
%title('Tensão aplicada no Estator','FontSize',12);
legend('va');
xlabel('Tempo [s]', 'FontSize',10);
ylabel('Tensão [V]', 'FontSize',10);
set(gca,'linewidth',1.2);
grid on;
% Figura 2:
% Plotagem da Rotação:
figure;
plot(tt_410,wrmec_410(1:length(tt_410))*60/(2*pi),'k', 'linewidth',0.7);
% xlim ( [ 0 0.6 ] );
ylim ( [ 0 2000 ] );
%title('Velocidade [RPM]','FontSize',12);
legend('rpm');
xlabel('Tempo [s]', 'FontSize',10);
ylabel('Velocidade [rpm]', 'FontSize',10);
set(gca,'linewidth',1.2);
grid on;
% Figura 3:
% Plotagem do Torque Eletromagnético:
figure;
plot(tt_410,Te_410,'k', 'linewidth',0.7);
% xlim ( [ 0 0.6 ] );
ylim ( [ 0 35 ] );
%title('Torque Eletromagnético','FontSize',12);
legend('Te');
xlabel('Tempo [s]', 'FontSize',10);
ylabel('Torque Eletromagnético [N.m]', 'FontSize',10);
set(gca,'linewidth',1.2);
grid on;
% Figura 4:
% Plotagem do Toque vs Velocidade:
figure;
plot(wrmec_410*60/(2*pi),Te_410,'k', 'linewidth',0.7);
xlim ( [ 0 2000 ] );
% ylim ( [ 0 0.6 ] );
%title('Torque vs Velocidade [RPM]','FontSize',12);
legend('Te vs rpm');
xlabel('Velocidade [rpm]', 'FontSize',10);
ylabel('Torque Eletromagnético [N.m]', 'FontSize',10);
set(gca,'linewidth',1.2);
grid on;
% Figura 5:
% Plotagem da Corrente na fase A do Estator:
figure;
plot(tt_410,iass_410(1:length(tt_410)),'k', 'linewidth',0.7);
% xlim ( [ 0 0.6 ] );
% ylim ( [ 0 0.6 ] );
%title('Corrente na Fase A do Estator','FontSize',12);
103
legend('A');
xlabel('Tempo [s]','FontSize',10);
ylabel('Corrente no Estator [A]','FontSize',10);
set(gca,'linewidth',1.2);
grid on;
% Figura 6:
% Plotagem da Correntes na fase A do Rotor:
figure;
plot(tt_410,iarr_410(1:length(tt_410)),'k', 'linewidth',0.7);
% xlim ( [ 0 2 ] );
% ylim ( [ 0 0.6 ] );
%title('Corrente na Fase A do Rotor','FontSize',12);
legend('A');
xlabel('Tempo [s]','FontSize',10);
ylabel('Corrente no Rotor [A]','FontSize',10);
set(gca,'linewidth',1.2);
grid on;
% Figura 7:
% Plotagem do fluxo no Estator:
figure;
plot(tt_410,fass_410(1:length(tt_410)),'k', 'linewidth',0.7);
% xlim ( [ 0 0.6 ] );
ylim ( [ -0.8 0.8 ] );
%title('Fluxo na Fase A do Estator','FontSize',12);
legend('Wb');
xlabel('Tempo [s]','FontSize',10);
ylabel('Fluxo no Estator [Wb]','FontSize',10);
set(gca,'linewidth',1.2);
grid on;
% Figura 8:
% Plotagem do fluxo no Rotor:
figure;
plot(tt_410,farr_410(1:length(tt_410)),'k', 'linewidth',0.7);
% xlim ( [ 0 2 ] );
% ylim ( [ 0 0.6 ] );
%title('Fluxo na Fase A do Rotor','FontSize',12);
legend('Wb');
xlabel('Tempo [s]','FontSize',10);
ylabel('Fluxo no Rotor [Wb]','FontSize',10);
set(gca,'linewidth',1.2);
grid on;
% Figura 9:
figure;
plot(tt_410,vds_410,'k', tt_410,vqs_410, 'k-.', 'linewidth',0.7)
% xlim ( [ 0 0.6 ] );
% ylim ( [ 0 0.6 ] );
%title('Tensões no Estator (dq0)','FontSize',12);
legend('vds','vqs');
xlabel('Tempo [s]','FontSize',10);
ylabel('Tensão [V]','FontSize',10);
set(gca,'linewidth',1.2);
grid on;
104
% Figura 10:
figure;
plot(tt_410,ids_410,'k', tt_410,iqs_410, 'k-.', 'linewidth',0.7);
% xlim ( [ 0 0.6 ] );
% ylim ( [ 0 0.6 ] );
%title('Correntes do Estator (dq0)','FontSize',12);
legend('ids','iqs');
xlabel('Tempo [s]','FontSize',10);
ylabel('Corrente [A]','FontSize',10);
set(gca,'linewidth',1.2);
grid on;
% Figura 11:
figure;
plot(tt_410,fds_410,'k', tt_410,fqs_410, 'k-.', 'linewidth',0.7)
% xlim ( [ 0 0.6 ] );
% ylim ( [ 0 0.6 ] );
%title('Fluxo do Estator (dq0)','FontSize',12);
legend('fds','fqs');
xlabel('Tempo [s]','FontSize',10);
ylabel('Fluxo [Wb]','FontSize',10);
set(gca,'linewidth',1.2);
grid on;
%% POTÊNCIAS:
% Figura 12:
% Plotagem da...........
figure;
plot(tt_410, pout_410,'k', 'linewidth',0.7);
hold on;
plot(tt_410, pconv_410,'k--', 'linewidth',0.7);
hold on;
plot(tt_410, pin_410,'k-.', 'linewidth',0.7);
% xlim ( [ 0 2000 ] );
ylim ( [ 0 7000 ] );
%title('...........[.....]','FontSize',12);
legend('pout','pconv','pin');
xlabel('Tempo [s]' , 'FontSize',10);
ylabel('Potência [W]' , 'FontSize',10);
set(gca,'linewidth',1.2);
grid on