Este guia contém informações para auxiliar o
técnico de manutenção na rotina de
troubleshooting. O guia "Quick ATR Reset" deve
sempre ser utilizado apenas como referência. Para
efetuar procedimentos de Reset e testes dos sistemas
de LRU utilize os manuais atualizados referentes a
aeronave.
Steve Jobs
[2]
[3]
CONTENTS
ADC ........................................................................................ 7
ADC 1+2 ................................................................................. 8
AHRS ...................................................................................... 9
AHRS 1+2 ..............................................................................10
AHRS NOT ALIGN .................................................................10
ALT DISAGREE .....................................................................11
ATT DISAGREE .....................................................................12
AVNX CPM1 ..........................................................................13
AVNX CPM1+IOM22 ..............................................................14
AVNX CPM1+IOM23 ..............................................................15
AVNX CPM2 ..........................................................................16
AVNX CPM2+IOM12 ..............................................................17
AVNX CPM2+IOM13 ..............................................................18
AVNX IOM 12+13 ...................................................................19
AVNX IOM 12+22 ...................................................................19
AVNX IOM 12+23 ...................................................................20
AVNX IOM 13+22 ...................................................................20
AVNX IOM 13+23 ...................................................................21
AVNX IOM 22+23 ...................................................................21
[4]
AVNX IOM DC 12 .................................................................. 22
AVNX IOM DC 13 .................................................................. 22
AVNX IOM DC 22 .................................................................. 23
AVNX IOM DC 23 .................................................................. 23
AVNX SGL SWITCH ............................................................. 24
BAD CONF ........................................................................... 25
DATALINK ............................................................................ 25
DME LOSS ............................................................................ 26
FWS SGL CH ........................................................................ 27
GPWS ................................................................................... 28
HDG DISAGREE ................................................................... 29
HF ......................................................................................... 30
HF EMITTING........................................................................ 31
IAS DISAGREE ..................................................................... 32
MFC 1A ................................................................................. 32
MFC 1A + 1B ........................................................................ 33
MFC 1A + 2A ........................................................................ 33
MFC 1A + 2B ........................................................................ 34
MFC 1B ................................................................................. 34
MFC 1B + 2A ........................................................................ 35
MFC 1B + 2B ........................................................................ 35
[5]
MFC 2A ..................................................................................36
MFC 2A + 2B .........................................................................36
MFC 2B ..................................................................................37
RAD-ALT ...............................................................................38
RAD-ALT LOSS .....................................................................39
RMS .......................................................................................40
SGL DME ...............................................................................41
TCAS .....................................................................................42
TERRAIN ...............................................................................43
VHF ........................................................................................44
XPDR .....................................................................................45
Flight attendant Panel ..........................................................46
Functional Item Number / Designation ................................47
[6]
ADC
ALERT DESCRIPTION: ONE ADC FAIL
MAINTENANCE ACTION:
Open during 5 sec. then close C/B MFC/1A AUX/ADC1 HOT
SPLY (B1) and PRIM REF/ADC1/ICP CAPT EMER SPLY (D5)
(21VU) to reset ADC1.
Quick reference:
Minimum Equipment List MEL 34-11-01
Functional Item Number 1FL1
Designation COMPUTER-AIR DATA, 1
Functional Item Number 1FL2
Designation COMPUTER-AIR DATA, 2
[7]
ADC 1+2
ALERT DESCRIPTION: ADC 1+2 LOSS
[8]
AHRS
ALERT DESCRIPTION: ONE AHRS FAIL
MAINTENANCE ACTION:
Open during 5 sec. then close C/B ATT/HDG/AHRS1 NORM
SPLY (D3) and ATT/HDG/AHRS1 AUX SPLY (C3) (21VU) to
reset AHRS1.
Quick reference:
Minimum Equipment List MEL 34-20-1
Functional Item Number 1FP1
Designation REFERENCE UNIT-ATTITUDE AND HEADING, AHRU 1
Functional Item Number 1FP2
Designation REFERENCE UNIT-ATTITUDE AND HEADING, AHRU 2
[9]
AHRS 1+2
ALERT DESCRIPTION: AHRS 1+2 LOSS
MAINTENANCE ACTION:
Parking brake engaged, open during 5 sec. then close C/B
ATT/HDG/AHRS1 NORM SPLY (D3),
ATT/HDG/AHRS1 AUX SPLY (C3),
ATT/HDG/AHRS2 AUX SPLY-GND (D4) and
ATT/HDG/AHRS2 NORM SPLY (C4) (21VU).
Quick reference:
Minimum Equipment List MEL 34-20-1
[ 10 ]
ALT DISAGREE
ALERT DESCRIPTION: ALTITUDE DISAGREE
MAINTENANCE ACTION:
Open during 5 sec. then close C/B
MFC/1A AUX/ADC1 HOT SPLY (B1),
PRIM REF/ADC1/ICP CAPT EMER SPLY (D5) and
PRIM REF/ADC2/ICP F/O GND SPLY (B5) (21VU).
Quick reference:
Minimum Equipment List MEL 34-20-1
[ 11 ]
ATT DISAGREE
ALERT DESCRIPTION: ATTITUDE DISAGREE
MAINTENANCE ACTION:
Open during 5 sec. then close C/B
ATT/HDG/AHRS1 NORM SPLY (D3),
ATT/HDG/AHRS1 AUX SPLY (C3),
ATT/HDG/AHRS2 AUX SPLY-GND (D4) and
ATT/HDG/AHRS2 NORM SPLY (C4) (21VU).
Quick reference:
Minimum Equipment List MEL 34-20-1
[ 12 ]
AVNX CPM1
ALERT DESCRIPTION: AVNX CPM 1 LOSS
MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM1/IOM-S1 (D6)
(21VU) to reset CPM1.
Quick reference:
Minimum Equipment List MEL 42-11-2
[ 13 ]
AVNX CPM1+IOM22
ALERT DESCRIPTION: AVNX CPM 1 + IOM 22 LOSS
MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM1/IOM-S1 (D6)
(21VU) to reset CPM1.
Quick reference:
Minimum Equipment List MEL 42-11-2
[ 14 ]
AVNX CPM1+IOM23
ALERT DESCRIPTION: AVNX CPM 1 + IOM 23 LOSS
MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM1/IOM-S1 (D6)
(21VU) to reset CPM1.
Quick reference:
Minimum Equipment List MEL 42-11-2
[ 15 ]
AVNX CPM2
ALERT DESCRIPTION: AVNX CPM 2 LOSS
MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM2/IOM-S2 NORM
SPLY (C6) (21VU) to reset CPM2.
Quick reference:
Minimum Equipment List MEL NO GO item
[ 16 ]
AVNX CPM2+IOM12
ALERT DESCRIPTION: AVNX CPM 2 + IOM 12 LOSS
MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM2/IOM-S2 NORM
SPLY (C6) (21VU) to reset CPM2.
Quick reference:
Minimum Equipment List MEL NO GO item
[ 17 ]
AVNX CPM2+IOM13
ALERT DESCRIPTION: AVNX CPM 2 + IOM 13 LOSS
MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B CAC/CPM2/IOM-S2 NORM
SPLY (C6) (21VU) to reset CPM2.
Quick reference:
Minimum Equipment List MEL NO GO item
[ 18 ]
AVNX IOM 12+13
ALERT DESCRIPTION: AVNX IOM 12 + 13 LOSS
[ 19 ]
AVNX IOM 12+23
ALERT DESCRIPTION: AVNX IOM 12 + 23 LOSS
[ 20 ]
AVNX IOM 13+23
ALERT DESCRIPTION: AVNX IOM 13 + 23 LOSS
[ 21 ]
AVNX IOM DC 12
ALERT DESCRIPTION: AVNX IOM 12 LOSS
Quick reference:
Minimum Equipment List MEL NO GO item
AVNX IOM DC 13
ALERT DESCRIPTION: AVNX IOM 13 LOSS
Quick reference:
Minimum Equipment List MEL NO GO item
[ 22 ]
AVNX IOM DC 22
ALERT DESCRIPTION: AVNX IOM 22 LOSS
Quick reference:
Minimum Equipment List MEL NO GO item
AVNX IOM DC 23
ALERT DESCRIPTION: AVNX IOM 23 LOSS
Quick reference:
Minimum Equipment List MEL NO GO item
[ 23 ]
AVNX SGL SWITCH
ALERT DESCRIPTION: AVNX SGL SWITCH
MAINTENANCE ACTION:
Parking brake or Gustlock engaged and engines 1 and 2 off.
Open during 5 sec. then close C/B
CAC/IOM-DC/12 (D8),
CAC/IOM-DC/22 (C8),
CAC/IOM-DC/13 (D9) and
CAC/IOM-DC/23 (C9) (21VU).
Quick reference:
Minimum Equipment List MEL NO GO item
[ 24 ]
BAD CONF
ALERT DESCRIPTION: None
Quick reference:
Minimum Equipment List MEL 31-60-1
DATALINK
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Open during 5 sec. then close C/B COM/ACARS CMU (B16)
(21VU).
Quick reference:
Minimum Equipment List MEL 23-24-1
[ 25 ]
DME LOSS
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Open during 5 sec. then close C/B NAV/COM/SURV/DME1
(D17) (21VU) to reset DME1.
Quick reference:
Minimum Equipment List MEL 34-51-1
[ 26 ]
FWS SGL CH
ALERT DESCRIPTION: AVNX FWS SGL CH
MAINTENANCE ACTION:
Make sure that parking brake is "ON" (or Gustlock engaged)
and engines 1 and 2 off.
Quick reference:
Minimum Equipment List MEL NO GO item
[ 27 ]
GPWS
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Open C/B SUR/T2CAS/T-R (A22) (21VU) during 5 sec. then
close it to reset computer T2CAS.
Quick reference:
Minimum Equipment List MEL 34-48-2
[ 28 ]
HDG DISAGREE
ALERT DESCRIPTION: HEADING DISAGREE
MAINTENANCE ACTION:
Open during 5 sec. then close C/B
ATT/HDG/AHRS1 NORM SPLY (D3),
ATT/HDG/AHRS1 AUX SPLY (C3),
ATT/HDG/AHRS2 AUX SPLY-GND (D4) and
ATT/HDG/AHRS2 NORM SPLY (C4) (21VU).
Quick reference:
Minimum Equipment List MEL 34-20-1
See page number “12”
[ 29 ]
HF
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Open during 5 sec. then close C/B HF1/T-R () to reset HF1.
Quick reference:
Minimum Equipment List MEL 23-11-1
[ 30 ]
HF EMITTING
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Open during 5 sec. then close C/B HF1/T-R () to reset HF1.
Quick reference:
Minimum Equipment List MEL 23-11-1
[ 31 ]
IAS DISAGREE
ALERT DESCRIPTION: IAS DISAGREE
MAINTENANCE ACTION:
Open during 5 sec. then close C/B PRIM REF/ADC1/ICP CAPT
EMER SPLY (D5) and PRIM REF/ADC2/ICP F/O GND SPLY
(B5) (21VU).
Quick reference:
Minimum Equipment List MEL 34-13-1
MFC 1A
ALERT DESCRIPTION: MFC 1A FAULT
MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1A,
P/BSW – MFC/1B and P/BSW – MFC/2B, wait 5 sec.
Then press P/BSW – MFC/1B and P/BSW – MFC/2B and when
they stop to flash, press P/BSW – MFC/1A.
Quick reference:
Minimum Equipment List MEL NO GO ITEM
[ 32 ]
MFC 1A + 1B
ALERT DESCRIPTION: MFC 1A + 1B FAULT
MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1A,
P/BSW – MFC/1B and P/BSW – MFC/2B, wait 5 sec.
Then press P/BSW – MFC/2B and when it stop to flash, press
P/BSW – MFC/1A and P/BSW – MFC/1B.
Quick reference:
Minimum Equipment List MEL NO GO ITEM
MFC 1A + 2A
ALERT DESCRIPTION: MFC 1A + 2A FAULT
MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1A,
P/BSW – MFC/2A, P/BSW – MFC/1B and P/BSW – MFC/2B,
wait 5 sec.
Then press P/BSW – MFC/1B and P/BSW – MFC/2B and when
they stop to flash, press P/BSW – MFC/1A and P/BSW –
MFC/2A.
Quick reference:
Minimum Equipment List MEL NO GO ITEM
[ 33 ]
MFC 1A + 2B
ALERT DESCRIPTION: MFC 1A + 2B FAULT
MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1A,
P/BSW – MFC/2B and P/BSW – MFC/1B, wait 5 sec.
Then press P/BSW – MFC/1B and when it stop to flash, press
P/BSW – MFC/1A and P/BSW – MFC/2B.
Quick reference:
Minimum Equipment List MEL NO GO ITEM
MFC 1B
ALERT DESCRIPTION: MFC 1B FAULT
MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1B
and P/BSW – MFC/2B, wait 5 sec.
Then press P/BSW – MFC/2B and when it stop to flash, press
P/BSW – MFC/1B.
Quick reference:
Minimum Equipment List MEL NO GO ITEM
[ 34 ]
MFC 1B + 2A
ALERT DESCRIPTION: MFC 1B + 2A FAULT
MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1B,
P/BSW – MFC/2B, P/BSW – MFC/2B, wait 5 sec.
Then press P/BSW – MFC/2B and when it stop to flash, press
P/BSW – MFC/1B and P/BSW – MFC/2B.
Quick reference:
Minimum Equipment List MEL NO GO ITEM
MFC 1B + 2B
ALERT DESCRIPTION: MFC 1B + 2B FAULT
MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/1B,
P/BSW – MFC/2B, P/BSW – MFC/1A and P/BSW – MFC/2B,
wait 5 sec.
Then press P/BSW – MFC/1A and P/BSW – MFC/2B and when
they stop to flash, press P/BSW – MFC/1B and P/BSW –
MFC/2B.
Quick reference:
Minimum Equipment List MEL NO GO ITEM
[ 35 ]
MFC 2A
ALERT DESCRIPTION: MFC 2A FAULT
MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/2B,
P/BSW – MFC/1B and P/BSW – MFC/2B, wait 5 sec.
Then press P/BSW – MFC/1B and P/BSW – MFC/2B and when
they stop to flash, press P/BSW – MFC/2B.
Quick reference:
Minimum Equipment List MEL NO GO ITEM
MFC 2A + 2B
ALERT DESCRIPTION: MFC 2A + 2B FAULT
MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/2B,
P/BSW – MFC/2B and P/BSW – MFC/1B, wait 5 sec.
Then press P/BSW – MFC/1B and when it stop to flash, press
P/BSW – MFC/2B and P/BSW – MFC/2B.
Quick reference:
Minimum Equipment List MEL NO GO ITEM
[ 36 ]
MFC 2B
ALERT DESCRIPTION: MFC 2B FAULT
MAINTENANCE ACTION:
On panel 25VU, depress the pushbuttons P/BSW – MFC/2B
and P/BSW – MFC/1B, wait 5 sec.
Then press P/BSW – MFC/1B and when it stop to flash, press
P/BSW – MFC/2B.
Quick reference:
Minimum Equipment List MEL NO GO ITEM
[ 37 ]
RAD-ALT
ALERT DESCRIPTION: ONE RAD-ALT FAIL
MAINTENANCE ACTION:
Open during 5 sec. then close C/B NAV/COM/SUR/RA1 (D21)
(21VU).
Quick reference:
Minimum Equipment List MEL 34-42-1
[ 38 ]
RAD-ALT LOSS
ALERT DESCRIPTION: RAD-ALT LOSS
MAINTENANCE ACTION:
Open during 5 sec. then close C/B (D21) (21VU).
Quick reference:
Minimum Equipment List MEL 34-42-1
[ 39 ]
RMS
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Switch off DU2 during 5 sec. then switch on DU2. On MCDU go
to ACMS/AVS/CMS//SYSTEM REPORT/TEST/DU2.
Switch off DU4 during 5 sec. then switch on DU4. On MCDU go
to ACMS/AVS/CMS//SYSTEM REPORT/TEST/DU4.
Quick reference:
Minimum Equipment List MEL 31-60-1
[ 40 ]
SGL DME
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Open during 5 sec. then close C/B (17D) (21VU) to reset
DME1.
Perform a system test.
On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/DME1.
Quick reference:
Minimum Equipment List MEL 34-51-1
[ 41 ]
TCAS
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Open during 5 sec. then close C/B (A22) (21VU) to reset
computer T2CAS.
Quick reference:
Minimum Equipment List MEL 34-57-1
[ 42 ]
TERRAIN
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Open during 5 sec. then close C/B (A22) (21VU) to reset
computer T2CAS.
Quick reference:
Minimum Equipment List MEL 34-57-1
[ 43 ]
VHF
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Open during 5 sec. then close C/B (20D) (21VU) to reset VHF1.
Perform a system test.
On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/VHF1.
Open during 5 sec. then close C/B (20C) (21VU) to reset VHF2.
Perform a system test.
On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/VHF2.
Open during 5 sec. then close C/B (20B) (21VU) to reset VHF3.
Perform a system test.
On MCDU go to ACMS/AVS/”SYSTEM REPORT/TEST”/VHF3.
Quick reference:
Minimum Equipment List MEL 23-12-1
[ 44 ]
XPDR
ALERT DESCRIPTION: None
MAINTENANCE ACTION:
Open during 5 sec. then close C/B (19D) (21VU) to reset
XPDR1.
Perform a system test.
On MCDU go to
ACMS/AVS/”SYSTEM REPORT/TEST”/XPDR1/T2CAS.
Quick reference:
Minimum Equipment List MEL 34-57-1
[ 45 ]
Flight attendant Panel
ALERT DESCRIPTION: Panel frozen
MAINTENANCE ACTION:
Open during 5 sec. then close C/B (K25) and (K24) (122VU) or
press the reset pushbutton located on the front face of the FAP
to reset it.
Quick reference:
Minimum Equipment List MEL TBD
[ 46 ]
Functional Item Number / Designation
[ 47 ]
1SG TRANSMITTER RECEIVER TCAS
1SH1 TRANSPONDER-ATC, 1
1SH2 TRANSPONDER-ATC, 2
1TF1A1 CPM1
1TF1B1 IOM-S1
1TF1F1 IOM-AP1
1TF1G1 IOM-DC12
1TF1H1 IOM-DC13
1TF1S1 SWM1
1TF2A1 CPM2
1TF2B1 IOM-S2
1TF2F1 IOM-AP2
1TF2G1 IOM-DC22
1TF2H1 IOM-DC23
1TF2S1 SWM2
1TU FDAU/MPC
1UA1 MFC1
1UA2 MFC2
1WK1 INTEGRATED AVIONICS DISPLAY, PFD1
1WK2 INTEGRATED AVIONICS DISPLAY, PFD2
200FN IESI
201CG PITCH POWER TRIM BOX
203CG YAW POWER TRIM BOX
204QT FUEL CONTROL UNIT (FCU)
22CG ACTUATOR-ELEV TRIM,
28CG ACTUATOR-TRIM, RUDDER
2FS CLOCK-F/O
2SN1 ANTENNA GPS 1
2SN2 ANTENNA GPS 2
2WK INTEGRATED AVIONICS DISPLAY, EWD
3CA CTL PNL-AFCS
3ER1 TRANSMITTER-OIL TEMP, ENG1
3ER2 TRANSMITTER-OIL TEMP, ENG2
3WK1 INTEGRATED AVIONICS DISPLAY, MFD1
3WK2 INTEGRATED AVIONICS DISPLAY, MFD2
44KF1 AFU ENG1
44KF2 AFU ENG2
48DA PROBE-PITOT, F/O
4SA1 ANTENNA-RA TRANSMISSION
4SA2 ANTENNA-RA TRANSMISSION
[ 48 ]
4WK1 INDEX CONTROL PANEL, ICP1
4WK2 INDEX CONTROL PANEL, ICP2
5007CA CAPSTAN - AP ROLL
5018CA CAPSTAN - AP PITCH
5019CA CAPSTAN - AP YAW
51HM AMBIANT PRESSURE UNIT
55DA PROBE-PITOT, CAPT
58CG RELAY
5EM1 SENSOR-FUEL TEMP, ENG1
5EM2 SENSOR-FUEL TEMP, ENG2
5RC1 ANTENNA-VHF, 1
5RC2 ANTENNA-VHF, 2
5RC3 ANTENNA VHF3
5SA1 ANTENNA-RA RECEPTION
5SA2 ANTENNA-RA RECEPTION
5SG ANTENNA TCAS
5WK1 MULTI-FUNCTION CONTROL PANEL
5WK2 MULTI-FUNCTION CONTROL PANEL
60FP1 AHRU REMOVABLE MEMORY MODULE
60FP2 AHRU REMOVABLE MEMORY MODULE
6SG ANTENNA TCAS
6WK1 EFIS CONTROL PANEL LH SIDE
6WK2 EFIS CONTROL PANEL RH SIDE
7CA ACTUATOR-AP ROLL
7RB ECU-3000
7RE1 COUPLER-ANTENNA, HF1
7RE2 COUPLER-ANTENNA, HF2
7SQ ANTENNA RADAR
8FL1 PROBE-AIR TEMPERATURE, L
8FL2 PROBE-AIR TEMPERATURE, R
EEC1 ELECTRONIC ENGINE CONTROL
EEC2 ELECTRONIC ENGINE CONTROL
[ 49 ]